  • Code: SC751
  • Description: Bridge unit connection error
    The IOB cannot communicate with the bridge unit properly when the finisher is installed.
  • Causes: • Poor connection between the IOB and bridge unit • IOB defectivective
  • Code: SC752
  • Description: Finisher connection error
    The IOB cannot communicate with the finisher properly when the bridge unit is installed.
  • Causes: • Poor connection between the finisher and bridge unit • IOB defective
  • Code: SC760
  • Description: ADF gate abnormal
    The ADF Gate signal line between the ADF main board and the IOB is disconnected.
  • Causes: • ADF main board defective • Input/output board defective • Por connection (ADF Gate line) between the ADF main board and the IOB.
  • Code: SC770
  • Description: Shift tray motor error (optional shift tray unit)
    The shift tray half-turn sensor is not activated within a certain time after the shift tray motor turned on.
  • Causes: • Shift tray motor defective • Shift tray half-turn sensor defective
  • Code: SC900
  • Description: Total counter error
  • Causes: • NVRAM defective
  • Code: SC901
  • Description: Mechanical Total Counter
    The mechanical total counter is not working properly.
  • Causes: • Mechanical total counter defective • IOB defective • Disconnected mechanical total counter
  • Code: SC921
  • Description: MSU hardware error
    The hardware of the MSU is defective.
  • Causes: • EMB (Copier feature expander) defective • BICU defective defective
  • Code: SC980
  • Description: Program loading error
    The program cannot load properly.
  • Causes: • The connection between the BICU and the IC board is poor. • BICU board defective • IC board or the program defective NOTE: This SC should be cleared by trying to download again from an IC card.