Code :
- Code: SC129
- Description: Scanner motor speed control error
The scanner speed is out of standard during scanning.
- Causes: • Scanner motor defective • PSU defective • MCU defective • Scanner drive defective
- Code: SC130
- Description: SBU error
When the main switch is turned on, the BICU cannot receive the correct signal from the SBU.
- Causes: • SBU defective • BICU defective • Cable between SBU and BICU defective
- Code: SC300
- Description: Charge corona output error 1
The feedback voltage from the charge corona unit is too high.
- Causes: • Charge P.P. defective • Poor charge corona unit connection
- Code: SC301
- Description: Charge corona output error 2
The control PWM for the charge corona unit is too high.
- Causes: • Charge P.P. defective • Poor charge corona unit connection
- Code: SC302
- Description: Charge corona output error 3
The control PWM for the charge grid is too high.
- Causes: • Charge P.P. defective • Poor charge corona unit connection
- Code: SC303
- Description: Charge corona output error 4
The feedback voltage from the charge grid is too high.
- Causes: • Charge P.P. defective • Poor charge corona unit connection
- Code: SC305
- Description: Charge corona wire cleaner error 1
The charge corona wire cleaner does not return to its home position.
- Causes: • Charge corona wire cleaner motor defective • Charge P.P. defective • IOB defective
- Code: SC306
- Description: Charge corona wire cleaner error 2
The charge corona wire cleaner motor connector is not connected.
- Causes: • The charge corona wire cleaner motor connector is not connected.