Description: Image storage address error
The SBICU receives an image data output request signal for data that is not stored in memory.
Causes: • SBICU defective
Code: SC400
Description: Transfer roller leak error
A transfer roller current leak signal is detected.
Causes: • Transfer P.P. defective • Poor connection between the transfer current terminal and the transfer P.P.
Code: SC401
Description: Transfer roller open error
The transfer roller current feedback signal is not detected
Causes: • Transfer P.P. defective • Poor connection between the transfer current terminal and the transfer P.P.
Code: SC430
Description: Quenching lamp error
When finishing the process control initial setting, the drum potential which is detected by the drum potential sensor is out of the normal range
Causes: • Quenching lamp defective • Poor connection between quenching lamp and charge power pack
Code: SC440
Description: Main motor lock
The main motor lock signal remains low for 2 seconds while the main motor is on.
Causes: • Too much load on the drive mechanism • Main motor defective
Code: SC441
Description: Development motor lock
The development motor lock signal remains low for 2 seconds while the development motor is on.
Causes: • Too much load on the drive mechanism • Development motor defective
Code: SC493
Description: Exhaust fan motor lock
The exhaust fan motor lock signal remains high for 5 seconds while the exhaust fan motor is on.
Causes: • Exhaust fan motor defective • Too much load on the fan