Code: 544

Description: Fusing low temperature error
A fusing temperature of lower than 100°C is detected for 1 second by the fusing thermistor during operation or stand-by mode.
Causes: • Fusing lamp open • Fusing thermistor defective • Power supply board defective • Fusing thermistor open • Fusing thermostat open

Code: 546

Description: Unstable fusing temperature
The fusing temperature does not rise 3 °C or more within 5 seconds after the fusing lamp has been on over 8 seconds.
Causes: • Thermistor defective • Power supply unit defective

Code: 547

Description: Zero cross signal malfunction
Zero cross signals are not detected within 5 seconds after the main power switch is turned on, or are not detected within 1 second after operation begins.
Causes: • Power supply board defective • IOB defective • BiCU defective

Code: 620

Description: Communication error between IOB and ADF
The IOB does not receive a response from the ADF main board for 4 seconds or more.
Causes: • Poor connection between the IOB and ADF main board (DF connector) • ADF main board defective • IOB defective

Code: 691

Description: Communication error between BiCU and fax controller
The BiCU board cannot communicate with the fax controller.
Causes: • Poor connection between the BiCU board and the fax controller • BiCU board defective • Fax controller defective

Code: 692

Description: Communication error between BiCU and printer controller
The BiCU board cannot communicate with the printer controller.
Causes: • Poor connection between the BiCU board and the printer controller. • BiCU board defective • Printer controller defective

Code: 695

Description: Fax firmware error
The fax program cannot be started.
Causes: • The fax firmware download has not been completed correctly. Try again.

Code: 760

Description: ADF gate abnormal
The ADF Gate signal line between the ADF main board and the IOB is disconnected.
Causes: • ADF main board defective • Input/output board defective • Poor connection (ADF Gate line) between the ADF main board and the IOB.