Các lỗi thường gặp

Code :
  • Code: 544
  • Description: Fusing low temperature error
    A fusing temperature of lower than 100°C is detected for 1 second by the fusing thermistor during operation or stand-by mode.
  • Causes: • Fusing lamp open • Fusing thermistor defective • Power supply board defective • Fusing thermistor open • Fusing thermostat open
  • Code: 546
  • Description: Unstable fusing temperature
    The fusing temperature does not rise 3 °C or more within 5 seconds after the fusing lamp has been on over 8 seconds.
  • Causes: • Thermistor defective • Power supply unit defective
  • Code: 547
  • Description: Zero cross signal malfunction
    Zero cross signals are not detected within 5 seconds after the main power switch is turned on, or are not detected within 1 second after operation begins.
  • Causes: • Power supply board defective • IOB defective • BiCU defective
  • Code: 620
  • Description: Communication error between IOB and ADF
    The IOB does not receive a response from the ADF main board for 4 seconds or more.
  • Causes: • Poor connection between the IOB and ADF main board (DF connector) • ADF main board defective • IOB defective
  • Code: 691
  • Description: Communication error between BiCU and fax controller
    The BiCU board cannot communicate with the fax controller.
  • Causes: • Poor connection between the BiCU board and the fax controller • BiCU board defective • Fax controller defective
  • Code: 692
  • Description: Communication error between BiCU and printer controller
    The BiCU board cannot communicate with the printer controller.
  • Causes: • Poor connection between the BiCU board and the printer controller. • BiCU board defective • Printer controller defective
  • Code: 695
  • Description: Fax firmware error
    The fax program cannot be started.
  • Causes: • The fax firmware download has not been completed correctly. Try again.
  • Code: 760
  • Description: ADF gate abnormal
    The ADF Gate signal line between the ADF main board and the IOB is disconnected.
  • Causes: • ADF main board defective • Input/output board defective • Poor connection (ADF Gate line) between the ADF main board and the IOB.