Các lỗi thường gặp

Code :
  • Code: 611
  • Description: Communication break error between BICU and ADF
    The BICU receives a break signal from the ADF main board.
  • Causes: • Serial line connecting BICU and ADF unstable • External noise • ADF main board defective • BICU board defective
  • Code: 612
  • Description: Communication command error between BICU and ADF
    The BICU sends a command to the ADF main board that it cannot execute.
  • Causes: • Abnormal operation performed by software
  • Code: 620
  • Description: Communication timeout error between BICU and finisher or mailbox
    The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the finisher or mailbox.
  • Causes: • Serial line connecting BICU and finisher unstable • External noise • BICU board and finisher main board connection defective or loose • Finisher main board defective • BICU board defective
  • Code: 621
  • Description: Communication timeout error between BICU and finisher or mailbox
    A break (low) signal was received from the finisher or the mailbox.
  • Causes: • Serial line connecting BICU and finisher unstable • External noise
  • Code: 623
  • Description: Communication timeout error between BICU and paper tray unit
    The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the paper tray unit.
  • Causes: • Serial line connecting BICU and paper tray unit unstable • External noise • BICU board and paper tray main board connection defective or loose • Paper tray main board defective • BICU board defective
  • Code: 624
  • Description: Communication break error between BICU and paper tray unit
    The BICU cannot communicate with the paper tray unit normally as a result of receiving a break signal.
  • Causes: • Serial line connecting BICU and paper tray unit unstable • External noise • BICU board and LCT main board connection defective or loose • Optional paper feed unit interface board defective • BICU board defective
  • Code: 626
  • Description: Communication timeout error between BICU and LCT
    The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the LCT.
  • Causes: • Serial line connecting BICU and LCT unit unstable • External noise • BICU board and LCT main board connection defective or loose • LCT interface board defective • BICU board defective
  • Code: 627
  • Description: Communication break error between BICU and LCT
    The BICU cannot communicate with the LCT unit normally as a result of receiving a break signal.
  • Causes: • Serial line connecting BICU and LCT unit unstable • External noise • BICU board and LCT main board connection defective or loose • LCT interface board defective • BICU board defective