Code: 821

Description: Self-Diagnostic Error: ASIC
The ASIC returned an error during the self-diagnostic test because the ASIC and CPU timer interrupts were compared and determined to be out of range.
Causes: • Controller board defective

Code: 823

Description: Self-diagnostic Error: Network Interface
The network interface board returned an error during the self-diagnostic test.
Causes: • Network interface board defective • Controller board defective

Code: 824

Description: Self-diagnostic Error: NVRAM
The resident non-volatile RAM returned an error during the self-diagnostic test.
Causes: • Replace the NVRAM on the controller board • Replace the controller board

Code: 826

Description: Self-diagnostic Error: NVRAM/Optional NVRAM
The NVRAM or optional NVRAM returned an error during the self-diagnostic test.
Causes: • Replace the NVRAM on the controller board

Code: 827

Description: Self-diagnostic Error: RAM
The resident RAM returned a verify error during the self-diagnostic test.
Causes: • Download controller firmware again

Code: 828

Description: Self-diagnostic Error: ROM
The resident read-only memory returned an error during the self-diagnostic test.
Causes: • Controller board defective • Download controller firmware again

Code: 829

Description: Self-diagnostic Error: Optional RAM
The optional RAM returned an error during the self-diagnostic test.
Causes: • Replace the optional memory board • Controller board defective

Code: 838

Description: Self-diagnostic Error: Clock Generator
A verify error occurred when setting data was read from the clock generator via the I2C bus.
Causes: • Replace the controller board