Description: Tandem tray lift error (optional LCT)
The lower limit sensor is not activated after the paper tray lift motor has been on to lower the tandem tray for 8 seconds.
Causes: • Paper tray lift motor defective • Lower limit sensor defective • Too much load on the drive mechanism
Description: Rear fence drive error (optional LCT)
The return position sensor is not activated after the rear fence drive motor has been on to lower the tandem tray for 8 seconds.
Causes: • Rear fence motor defective • Return position sensor defective • Too much load on the drive mechanism
Description: Side fence drive error (optional LCT)
The side fence positioning sensor is not activated for more 3 seconds when the paper stack in the left tray is moved to the right tray. The side fence close sensor is not activated for more 3 seconds after moving the paper stack to the right tray.
Causes: • Side fence motor defective • Side fence position sensor defective • Side fence close sensor defective • Too much load on the drive mechanism
Description: Fusing thermistor open
The fusing temperature detected by the thermistor was below 55 °C for 15 seconds or below 75 °C for 20 seconds.
Causes: • Fusing thermistor defective or out of position • Fusing lamp open • Fusing thermofuse open • Power supply board defective • Poor connection of the fusing unit
Description: Fusing temperature warm-up error
The fusing temperature does not reach 155 °C within 60 seconds after the main switch is turned on.
Causes: • Fusing thermistor defective or out of position • Fusing lamp open • Fusing thermofuse open • Power supply board defective • Poor connection of the fusing unit
Description: Unstable fusing temperature
Fusing temperature more than 60 °C: The fusing temperature does not rise 2°C or more within 6 seconds after the fusing lamp has been on. Fusing temperature 60 °C or less: The fusing temperature does not rise 2°C or more during a 6 second interval (the 6 s timer starts 14 s after the fusing lamp turned on).
Causes: • Thermistor defective • Poor connection of the fusing unit • Power supply unit defective
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.