Code: 955

Description: Image transfer error
The controller is not able to transfer images when the engine needs them.
Causes: • Application program defective

Code: 964

Description: Status error (laser optics housing unit)
The optics housing unit does not become ready within 17 seconds after the request.
Causes: • Software defective

Code: 981

Description: NVRAM error
The machine detects a discrepancy in the NVRAM write/read data when attempting to save actual data to the NVRAM (i.e. during actual use).
Causes: • NVRAM defective • Poor connection between BICU and NVRAM • NVRAM is not connected • BICU defective

Code: 982

Description: Localization error
The localization settings in the nonvolatile ROM and RAM are different
Causes: • First machine start after the NVRAM is replaced • Incorrect localization setting • NVRAM defective

Code: 984

Description: Print image transfer error
Print images are not transferred.
Causes: • Controller defective • BICU board defective • Poor connection between controller and BICU

Code: 990

Description: Software performance error
The software attempted to perform an unexpected operation.
Causes: • Software defective • Internal parameter incorrect • Insufficient working memory • When this SC occurs, the file name, address, and data will be stored in NVRAM. This information can be checked by using SP7-403. Note the above data and the situation in which this SC occurs. Then report the data and conditions to your technical control center.

Code: 991

Description: Software continuity error
The software attempted to perform an unexpected operation. However, unlike SC990, the object of the error is continuity of the software.
Causes: • No operation required. This SC code does not appear on the panel, and is only logged.

Code: 992

Description: Unexpected Software Error
Software encountered an unexpected operation not defined under any SC code.
Causes: • Software defective • An error undetectable by any other SC code occurred
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie