Các lỗi thường gặp

Code :
  • Code: 402
  • Description: Transfer roller leak error 2
    A current leak signal for the transfer roller is detected. A current feedback signal for the transfer roller is not detected.
  • Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
  • Code: 500
  • Description: Main motor lock
    A main motor lock signal is not detected for more than 7 consecutive checks (700 ms) after the main motor starts to rotate, or the lock signal is not detected for more than 7 consecutive checks during rotation after the last signal.
  • Causes: • Too much load on the drive mechanism • Main motor defective
  • Code: 502
  • Description: Tray 2 lift motor malfunction (Optional Paper Tray units)
    The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
  • Causes: • Paper lift sensor defective • Tray lift motor defective • Too much load on the drive mechanism • Poor tray lift motor connection
  • Code: 503
  • Description: Tray 3 lift motor malfunction (optional paper tray units)
    The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
  • Causes: • Paper lift sensor defective • Tray lift motor defective • Too much load on the drive mechanism • Poor tray lift motor connection
  • Code: 504
  • Description: Tray 4 lift motor malfunction (optional two-tray paper tray unit)
    The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
  • Causes: • Paper lift sensor defective • Tray lift motor defective • Too much load on the drive mechanism • Poor tray lift motor connection
  • Code: 506
  • Description: Paper feed motor lock (optional paper tray units)
    A motor lock signal is not detected for more than 1.5 s or the lock signal is not detected for more than 1.0 s during rotation.
  • Causes: • Paper feed motor defective • Too much load on the drive mechanism
  • Code: 541
  • Description: Fusing thermistor open (center)
    The fusing temperature detected by the thermistor is below 71°C and is not corrected after the main power switch is turned on.
  • Causes: • Fusing thermistor defective or out of position • Power supply board defective • Loose connectors
  • Code: 542
  • Description: Fusing temperature warm-up error (center)
    The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 25 or 35 seconds.
  • Causes: • Fusing thermistor defective or out of position • Fusing lamp open • Power supply board defective