Description: Counter device error 1
After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device.
Code: 633
Description: Counter device error 2
After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device.
Code: 634
Description: Counter device error 3
A backup RAM error was returned by the counter device.
Causes: • Counter device control board defective • Backup battery of counter device defective
Code: 635
Description: Counter device error 4
A backup battery error was returned by the counter device.
Causes: • Counter device control board defective • Backup battery of counter device defective
Code: 640
Description: SBCU control data transfer checksum error
A sampling of control data sent from the SBCU to the controller reveals a checksum error. Only the logging count is performed.
Description: Communication timeout error between SBCU and duplex unit
The SBCU cannot receive a response within 1 second from the duplex unit.
Causes: • Serial line connecting SBCU and duplex unit unstable • External noise • SBCU board and duplex main board connection defective or loose • Duplex main board defective • SBCU board defective
Code: 670
Description: Engine response error
After powering on the machine, a response is not received from the engine within 30 seconds.