Description: TD sensor error: Test value abnormal
The TD sensor output voltage is less than 0.5V or more than 5.0V after 10 consecutive times during copying.
Causes: • TD sensor defective • TD sensor not connected or connector damaged • Poor connection between the TD sensor and the I/O board (IOB) • I/O board (IOB) defective • Toner supply defective
Description: TD sensor error: Auto adjust error
During automatic adjustment of the TD sensor, output voltage is less than 1.8V or more than 4.8V during TD sensor initial setting.
Description: Development output abnormal
A development bias leak signal is detected. High voltage output to the development unit exceeded the upper limit (65%) for 60 ms.
Causes: • High voltage supply board defective • Poor connection at the development bias terminal • Poor connection at the high voltage supply board
Description: Transfer belt position sensor error
The transfer belt position sensor does not activate even if the transfer belt contact clutch has been switched on twice and rotated once.
Causes: • Main motor/drive malfunction • Transfer belt contact clutch defective • Transfer belt position sensor defective • Harness disconnected
Description: Transfer belt error
The transfer belt does not move away from the drum during ID sensor pattern checking.
Causes: • Main motor/drive malfunction • Transfer belt position sensor defective • Poor transfer belt position sensor connection • Transfer belt contact clutch defective