Description: Toner Supply Pump Motor Error
The toner supply pump motor lock signal did not change within 1 s while the motor is operating.
Causes: • Motor lock due to overload • BCU defective
Code: SC592
Description: Toner Bank Motor Error
An abnormal signal was received from the toner bank motor.
Causes: • Toner bank motor defective • Bank motor connector loose • Too much load on the drive mechanism
Code: SC593
Description: Toner Suction Motor Replace
The operation time of the motor is over 600 hours.
Causes: • Service life of the toner suction motor is finished. NOTE: A near-end message is displayed in the LCD when the operation time exceeds 570 hours.
Code: SC601
Description: Communication Error Between BCU and MCU
One or more of the following occurred: • The BCU cannot communicate with the MCU within 0.8 s after power on. • A BREAK signal was detected after connection between the BCU and MCU. • After a communication error, three tries to communicate with the MCU failed.
Causes: • Poor connection between BCU and MCU • BCU defective • MCU defective
Code: SC620
Description: Communication Error between BCU and ADF 1
The TXD and RXD signals between BCU and ADF main board do not stabilize.
Causes: • Poor connection between the BCU board and the ADF main board • Noise on interface cable
Code: SC621
Description: Communication Error between BCU and ADF 2
The TXD and RXD signals between BCU and ADF main board do not stabilize.
Causes: • Poor connection between the BCU board and the ADF main board • ADF main board defective • BCU board defective
Code: SC622
Description: Communication Error between BCU and ADF 3
Software error after abnormal user operation.
Causes: • Software error; switch the machine off/on
Code: SC625
Description: The BCU cannot communicate with the finisher properly.
The BCU cannot communicate with the finisher properly.
Causes: • Poor connection between the BCU board and the finisher main board • Finisher main board defective • BCU board defective • Noise on the interface cable