Các lỗi thường gặp

Code :
  • Code: SC591
  • Description: Toner Supply Pump Motor Error
    The toner supply pump motor lock signal did not change within 1 s while the motor is operating.
  • Causes: • Motor lock due to overload • BCU defective
  • Code: SC592
  • Description: Toner Bank Motor Error
    An abnormal signal was received from the toner bank motor.
  • Causes: • Toner bank motor defective • Bank motor connector loose • Too much load on the drive mechanism
  • Code: SC593
  • Description: Toner Suction Motor Replace
    The operation time of the motor is over 600 hours.
  • Causes: • Service life of the toner suction motor is finished. NOTE: A near-end message is displayed in the LCD when the operation time exceeds 570 hours.
  • Code: SC601
  • Description: Communication Error Between BCU and MCU
    One or more of the following occurred: • The BCU cannot communicate with the MCU within 0.8 s after power on. • A BREAK signal was detected after connection between the BCU and MCU. • After a communication error, three tries to communicate with the MCU failed.
  • Causes: • Poor connection between BCU and MCU • BCU defective • MCU defective
  • Code: SC620
  • Description: Communication Error between BCU and ADF 1
    The TXD and RXD signals between BCU and ADF main board do not stabilize.
  • Causes: • Poor connection between the BCU board and the ADF main board • Noise on interface cable
  • Code: SC621
  • Description: Communication Error between BCU and ADF 2
    The TXD and RXD signals between BCU and ADF main board do not stabilize.
  • Causes: • Poor connection between the BCU board and the ADF main board • ADF main board defective • BCU board defective
  • Code: SC622
  • Description: Communication Error between BCU and ADF 3
    Software error after abnormal user operation.
  • Causes: • Software error; switch the machine off/on
  • Code: SC625
  • Description: The BCU cannot communicate with the finisher properly.
    The BCU cannot communicate with the finisher properly.
  • Causes: • Poor connection between the BCU board and the finisher main board • Finisher main board defective • BCU board defective • Noise on the interface cable