Code: 547

Description: Zero cross signal error
One of the following occurred: 1) The fusing relay remained off for 50 ms after power on and continued to remain off after the after 3 attempts to detect the zero-cross signal. 2) During 11 zero-cross signal detections, two zero-cross signal detections were below 44 Hz. 3) The zero-cross signal could not be detected within 3 sec. after the fusing relay switched on.
Causes: • Switch the main switch off and on • Defective fusing relay, replace the PSU

Code: 548

Description: Fusing unit installation error
The machine cannot detect the fusing unit when the front cover and right cover are closed.
Causes: • Fusing unit is not installed • Fusing unit connection loose

Code: 557

Description: Zero-cross frequency over
The applied power ac frequency was detected less than 66 Hz more than 10 times, or less than 44 Hz one time.
Causes: • Nose on the ac power line

Code: 599

Description: 1-Bin tray motor lock
A 1-bin tray motor lock signal is not detected for more than 300 ms during rotation.
Causes: • 1-bin tray motor locked from overload • 1-bin tray motor defective • 1-bin tray motor connection loose

Code: 601

Description: Communication error between BICU and scanner unit
Within 800 ms after power on, after 3 attempts the BICU does not communicate with the SIB via the serial line.
Causes: • Serial line connecting the BICU and SIB defective • External noise on the serial line • SIB board defective • BICU board defective

Code: 610

Description: Communication timeout error between BICU and ADF
The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the ARDF
Causes: • BICU board and ADF main board serial line connection defective • External noise • ADF main board defective • BICU board defective

Code: 611

Description: Communication break error between BICU and ADF
The BICU receives a break signal from the ADF main board.
Causes: • Serial line connecting BICU and ADF unstable • External noise • ADF main board defective • BICU board defective

Code: 612

Description: Communication command error between BICU and ADF
The BICU sends a command to the ADF main board that it cannot execute.
Causes: • Abnormal operation performed by software