Description: Key/card counter device error 2
During communication with the device, the BCU received a break (Low) signal.
Causes: • The serial line from the device to the copier is unstable, disconnected, or defective.
Code: 634
Description: Key/card counter device error 3
The backup battery of the counter device RAM is low.
Causes: • Replace the RAM backup battery.
Code: 635
Description: Key/card counter device error 4
After installation of the device a message alerts user to a battery voltage abnormal error.
Causes: • Device control board defective • Device control board backup battery defective
Code: 670
Description: Engine startup error
The BCU failed to respond with the prescribed time when the machine was turned on.
Causes: • Connections between BCU and controller board are loose, disconnected, or damaged • Replace the BCU • Replace the controller board
Code: 672
Description: Controller startup error
• After power on, the line between the controller and the operation panel did not open for normal operation. • After normal startup, communication with the controller stopped.
Description: GAVD block I2C bus error
The I2C bus is defective.
Causes: • Replace the BICU.
Code: 700
Description: ARDF original pick-up malfunction
After the pick-up motor is turned on, the original stopper HP sensor is not detected.
Causes: Original stopper HP sensor (output abnormal) Pick-up motor defective (not rotating) Timing belt out of position • ADF main board defective
Code: 701
Description: ARDF original pick-up/paper lift mechanism malfunction
The original pick-up HP sensor does not activate three times consecutively after the pick-up motor has turned on.