Code: SC545

Description: Fusing overheat error 2
The fusing lamp stays on at full power for 30 seconds while in the stand-by condition after warming-up is completed.
Causes: • Fusing thermistor out of position

Code: SC546

Description: Fusing ready temperature malfunction
The fusing temperature goes 20 °C below or 20 °C over the stand-by temperature after warm-up is completed.
Causes: • Poor thermistor connector connection • Poor fusing unit connection

Code: SC547

Description: Zero cross signal malfunction
Zero cross signals are not detected within a certain period within 500 ms after the main power switch has been turned on.
Causes: • Power supply board defective • Noise on the ac power line

Code: SC548

Description: Fusing unit installation error
The machine cannot detect the fusing unit when the front cover and right cover are closed.
Causes: • Fusing unit is not installed • Poor fusing unit connection

Code: SC599

Description: 1-bin tray motor lock (optional 1-bin tray unit)
A 1-bin tray motor lock signal is not detected for more than 0.3 seconds during rotation.
Causes: • 1-bin tray motor defective • Too much load on the drive mechanism • Poor motor connector connection

Code: SC601

Description: Communication error between BICU and scanner unit
The BICU cannot communicate with the BIS board properly.
Causes: • Poor connection between the SIB and SIFB boards. • Poor connection between the SIFB and BICU boards. • SIB board defective • SIFB board defective • BICU board defective

Code: SC602

Description: Communication error between BICU and HDD control board
The BICU cannot communicate with the HDD control board properly.
Causes: • Poor connection between the BICU board and HDD control board • HDD control board defective • BICU board defective

Code: SC620-1

Description: Communication error between BICU and ADF 1
The BICU cannot receive a response signal three times when a communication error has occurred.
Causes: • Poor connection between the BICU board and ADF main board • ADF main board defective • BICU board defective
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie