Mã lỗi Ricoh Aficio 551 — Trang 2/18
Description: Scanner motor speed control error
The scanner speed is out of standard during scanning.
Causes: • Scanner motor defective • PSU defective • MCU defective • Scanner drive defective
Description: SBU error
When the main switch is turned on, the BICU cannot receive the correct signal from the SBU.
Causes: • SBU defective • BICU defective • Cable between SBU and BICU defective
Description: Charge corona output error 1
The feedback voltage from the charge corona unit is too high.
Causes: • Charge P.P. defective • Poor charge corona unit connection
Description: Charge corona output error 2
The control PWM for the charge corona unit is too high.
Causes: • Charge P.P. defective • Poor charge corona unit connection
Description: Charge corona output error 3
The control PWM for the charge grid is too high.
Causes: • Charge P.P. defective • Poor charge corona unit connection
Description: Charge corona output error 4
The feedback voltage from the charge grid is too high.
Causes: • Charge P.P. defective • Poor charge corona unit connection
Description: Charge corona wire cleaner error 1
The charge corona wire cleaner does not return to its home position.
Causes: • Charge corona wire cleaner motor defective • Charge P.P. defective • IOB defective
Description: Charge corona wire cleaner error 2
The charge corona wire cleaner motor connector is not connected.
Causes: • The charge corona wire cleaner motor connector is not connected.