Remedy: 1. Turn the main switch off and on. 2. Check the connection between the HDD and controller. 3. Check and replace the cables. 4. Replace the HDD. 5. Replace the controller.
Code: SC863
Description: HDD: Read error The data stored in the HDD cannot be read correctly.
Causes: • Defective HDD • Defective controller
Remedy: 1. Turn the main switch off and on. 2. Replace the HDD. 3. Replace the controller.
Code: SC864
Description: HDD: CRC error While reading data from the HDD or storing data in the HDD, data transmission fails.
Causes: • Defective HDD
Remedy: 1. Turn the main switch off and on. 2. Replace the HDD.
Code: SC865
Description: HDD: Access error An error is detected while operating the HDD.
Causes: • Defective HDD
Remedy: 1. Turn the main switch off and on. 2. Replace the HDD.
Code: SC900
Description: Electric counter error Abnormal data is stored in the counters.
Causes: • Defective NVRAM • Defective controller
Remedy: 1. Turn the main switch off and on. 2. Check the connection between the NVRAM and controller. 3. Replace the NVRAM. 4. Replace the controller.