Các lỗi thường gặp

Code :
  • Code: SC 734
  • Description: Finisher tray 2 shift motor error Tray 2 home position is not detected within a specified time after the tray 2 shift motor turns on.
  • Causes: • Loose connection • Defective tray shift 2 sensor • Defective tray 2 shift motor
  • Remedy: 1. Turn the main switch off and on. 2. Check if the connectors of the sensor and motor are properly connected. 3. Replace the tray shift 2 sensor. 4. Replace the tray 2 shift motor.
  • Code: SC 804
  • Description: Video input incomplete (K) • The scanner is requested to transfer video data, but does not issue the video transmission end command within the defined time.
  • Causes: • Board connector between controller and bridge board loose • Board connector between bridge board and IPU loose • IPU board defective • Controller board defective • Bridge board defective
  • Remedy: 1. Turn the main switch off and on. 2. Check the cable connection between controller and bridge board. 3. Check the cable connection between bridge board and IPU. 4. Replace the IPU board. 5. Replace the controller board. 6. Replace the bridge board.
  • Code: SC 805
  • Description: Video input incomplete (Y) • The scanner is requested to transfer video data, but does not issue the video transmission end command within the defined time.
  • Causes: • Board connector between controller and bridge board loose • Board connector between bridge board and IPU loose • IPU board defective • Controller board defective • Bridge board defective
  • Remedy: 1. Turn the main switch off and on. 2. Check the cable connection between controller and bridge board. 3. Check the cable connection between bridge board and IPU. 4. Replace the IPU board. 5. Replace the controller board. 6. Replace the bridge board.
  • Code: SC 806
  • Description: Video input incomplete (M) • The scanner is requested to transfer video data, but does not issue the video transmission end command within the defined time.
  • Causes: • Board connector between controller and bridge board loose • Board connector between bridge board and IPU loose • IPU board defective • Controller board defective • Bridge board defective
  • Remedy: 1. Turn the main switch off and on. 2. Check the cable connection between controller and bridge board. 3. Check the cable connection between bridge board and IPU. 4. Replace the IPU board. 5. Replace the controller board. 6. Replace the bridge board.
  • Code: SC 807
  • Description: Video input incomplete (C) • The scanner is requested to transfer video data, but does not issue the video transmission end command within the defined time.
  • Causes: • Board connector between controller and bridge board loose • Board connector between bridge board and IPU loose • IPU board defective • Controller board defective • Bridge board defective
  • Remedy: 1. Turn the main switch off and on. 2. Check the cable connection between controller and bridge board. 3. Check the cable connection between bridge board and IPU. 4. Replace the IPU board. 5. Replace the controller board. 6. Replace the bridge board.
  • Code: SC 808
  • Description: Video input incomplete (R) • The scanner is requested to transfer video data, but does not issue the video transmission end command within the defined time.
  • Causes: • Board connector between controller and bridge board loose • Board connector between bridge board and IPU loose • IPU board defective • Controller board defective • Bridge board defective
  • Remedy: 1. Turn the main switch off and on. 2. Check the cable connection between controller and bridge board. 3. Check the cable connection between bridge board and IPU. 4. Replace the IPU board. 5. Replace the controller board. 6. Replace the bridge board.
  • Code: SC 809
  • Description: Video input incomplete (G) • The scanner is requested to transfer video data, but does not issue the video transmission end command within the defined time.
  • Causes: • Board connector between controller and bridge board loose • Board connector between bridge board and IPU loose • IPU board defective • Controller board defective • Bridge board defective
  • Remedy: 1. Turn the main switch off and on. 2. Check the cable connection between controller and bridge board. 3. Check the cable connection between bridge board and IPU. 4. Replace the IPU board. 5. Replace the controller board. 6. Replace the bridge board.
  • Code: SC 810
  • Description: Video input incomplete (B) • The scanner is requested to transfer video data, but does not issue the video transmission end command within the defined time.
  • Causes: • Board connector between controller and bridge board loose • Board connector between bridge board and IPU loose • IPU board defective • Controller board defective • Bridge board defective
  • Remedy: 1. Turn the main switch off and on. 2. Check the cable connection between controller and bridge board. 3. Check the cable connection between bridge board and IPU. 4. Replace the IPU board. 5. Replace the controller board. 6. Replace the bridge board.