Description: Lower Transport Motor Error: 3K Finisher B830
No encoder pulse signal is detected for the lower transport motor within 600 ms. The 1st failure issues an original jam message, and the 2nd failure issues this SC code.
Causes: • Lower transport motor disconnected, defective
• Finisher connection to lower transport motor loose, defective
• Lower transport motor blocked by an obstruction
• Lower transport motor defective • Finisher main board defective
Code: SC731
Description: Upper Transport Motor Error (Proof Tray): 3K Finisher B830
No encoder pulse signal is detected for the upper transport motor within 600 ms. The 1st failure issues this SC code.
Causes: • Upper transport motor disconnected, defective
• Finisher connection to upper transport motor loose, defective
• Upper transport motor blocked by an obstruction
• Upper transport motor defective
• Finisher main board defective
Code: SC732
Description: Shift Tray Exit Motor: 3K Finisher B830
The shift tray exit motor is not operating.
Causes: • Motor harness loose, broken, defective
• Motor is blocked by an obstruction
• Motor defective
• Finisher main control board defective
Code: SC733
Description: Stapler Exit Motor: 3K Finisher B830
The stapler exit motor is not operating.
Causes: • Motor harness loose, broken, defective
• Motor is blocked by an obstruction
• Motor defective
• Finisher main control board defective
Code: SC734
Description: Upper Tray Junction Gate Motor: 3K Finisher B830
The upper tray junction gate HP sensor did not detect the gate at the home position within 200 ms after two attempts. -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open.
Causes: • Junction gate did not arrive at the home position within the specified time
• Junction gate did not leave the home position within the specified time
Code: SC735
Description: Staple Junction Gate Motor Error: 3K Finisher B830
The staple tray junction gate HP sensor did not detect the gate at the home position within 200 ms after two attempts. -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open.
Causes: • Junction gate did not arrive at the home position within the specified time
• Junction gate did not leave the home position within the specified time
Code: SC736
Description: Pre-Stack Junction Gate Motor Error: 3K Finisher B830
The pre-stack junction gate HP sensor did not detect the gate at the home position for within 200 ms after two attempts. -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open.
Causes: • Junction gate did not arrive at the home position within the specified time
• Junction gate did not leave the home position within the specified time
Code: SC737
Description: Pre-Stack Transport Motor Error: 3K Finisher B830
The pre-stack transport motor is not operating.
Causes: • Motor harness loose, broken, defective
• Motor is blocked by an obstruction
• Motor defective
• Finisher main control board defective