Code: 542

Description: Fusing temperature warm-up error (center)
The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 25 or 35 seconds.
Causes: - Fusing thermistor defective or out of position
- Fusing lamp open
- Power supply board defective

Code: 543

Description: Fusing overheat error (center)
The fusing temperature is over 230C for 1 second (detected by the thermistor).
Causes: - Fusing thermistor defective
- Power supply board defective

Code: 544

Description: Fusing overheat error (center) 2
The fusing temperature is over 250C for 1 second (detected by the fusing temperature monitor circuit).
Causes: - Fusing thermistor defective
- Power supply board defective

Code: 545

Description: Fusing lamp overheat error (center)
After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 12 consecutive seconds.
Causes: - Fusing thermistor defective or out of position
- Power supply board defective

Code: 546

Description: Unstable fusing temperature (center)
The fusing temperature varies 50C or more within 1 second, and this occurs 2 consecutive times.
Causes: - Thermistor defective or out of position
- Power supply unit defective

Code: 547

Description: Zero cross signal malfunction
Zero cross signals are not detected within 5 seconds after the main power switch is turned on, or are not detected within 1 second after operation begins.
Causes: - Power supply board defective
- BICU defective

Code: 551

Description: Fusing thermistor open (rear)
The fusing temperature detected by the thermistor is below 71C and is not corrected after the main power switch is turned on.
Causes: - Fusing thermistor defective or out of position
- Power supply board defective
- Loose connectors

Code: 552

Description: Fusing temperature warm-up error (rear)
The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 25 or 35 seconds.
Causes: - Fusing thermistor defective or out of position
- Fusing lamp open
- Power supply board defective