Mã lỗi Ricoh Aficio MP1600 — Trang 8/11
Description: Self-diagnostic Error: Network Interface
The network interface board returned an error during the self-diagnostic test.
Causes: - Network interface board defective
- Controller board defective
Description: Self-diagnostic Error: NVRAM
The resident non-volatile RAM returned an error during the self-diagnostic test.
Causes: - Replace the NVRAM on the controller board
- Replace the controller board
Description: Self-diagnostic Error: NVRAM/Optional NVRAM
The NVRAM or optional NVRAM returned an error during the self-diagnostic test.
Causes: - Replace the NVRAM on the controller board
Description: Self-diagnostic Error: RAM
The resident RAM returned a verify error during the self-diagnostic test.
Causes: - Download controller firmware again
Description: Self-diagnostic Error: ROM
The resident read-only memory returned an error during the self-diagnostic test.
Causes: - Controller board defective
- Download controller firmware again
Description: Self-diagnostic Error: Optional RAM
The optional RAM returned an error during the self-diagnostic test
Causes: - Replace the optional memory board
- Controller board defective
Description: Self-diagnostic Error: Clock Generator
A verify error occurred when setting data was read from the clock generator via the I2C bus
Causes: - Replace the controller board
Description: Network I/F Abnormal
NIB interface error.
Causes: - NIB defective
- Controller board defective