Các lỗi thường gặp

Code :
  • Code: 694
  • Description: Scanner board communication error
    • BICU does not get a signal from the scanner board for 1.5 seconds or more.
    • BICU gets a break-signal after completing the communication with the scanner board and does not get a signal from the scanner board for 10 seconds or more.
  • Causes: • Defective communication between BICU and scanner board
  • Code: 760
  • Description: ADF gate error 1
    The ADF sends the FGATE signal before it is requested to scan originals.
  • Causes: • Defective ADF board
    • Defective input/output board
    • Loose connection
  • Code: 761
  • Description: ADF gate abnormal 2
    The ADF does not send the FGATE signal within 30 seconds after the ADF starts scanning.
  • Causes: • Defective ADF connector
    • Defective SBU board
  • Code: 762
  • Description: ADF gate abnormal 3
    The ADF continues to send the FGATE signal for more than 60 seconds after the ADF starts scanning.
  • Causes: • Defective ADF connector
    • Defective SBU board
  • Code: 901
  • Description: Mechanical total counter error
    The polling module does not detect the mechanical total counter.
  • Causes: • Defective mechanical total counter
    • Defective BICU
    • Loose connection
  • Code: 903
  • Description: Engine total counter error
    The checksum of the total counter is not correct.
  • Causes: • Defective NVRAM on the BICU
  • Code: 928
  • Description: Memory error
    An error occurs during the memory check conducted when the main power switch is turned on or when the copier is recovering from the energy saver mode.
  • Causes: • Defective memory
    • Defective BICU
    • Loose connection between the BICU and the memory
  • Code: 929
  • Description: IMAC hardware error
    A memory control job is not completed within a certain period.
  • Causes: • Defective IMAC
    • Defective BICU
    • Loose connection