Các lỗi thường gặp

Code :
  • Code: 402
  • Description: Transfer roller leak error 2
    A current leak signal for the transfer roller is detected. A current feedback signal for the transfer roller is not detected.
  • Causes: • High voltage supply board defective
    • Poor connection of the PCU
    • Transfer/separation unit set incorrectly
    • Transfer roller damaged
  • Code: 500
  • Description: Main motor lock
    A main motor lock signal is not detected for more than 7 consecutive checks (700 ms) after the main motor starts to rotate, or the lock signal is not detected for more than 7 consecutive checks during rotation after the last signal.
  • Causes: • Too much load on the drive mechanism
    • Main motor defective
  • Code: 541
  • Description: Fusing thermistor open (center)
    The fusing temperature detected by the thermistor is below 71°C and is not corrected after the main power switch is turned on.
  • Causes: • Fusing thermistor defective or out of position
    • Power supply board defective
    • Loose connectors
  • Code: 542
  • Description: Fusing temperature warm-up error (center)
    The fusing temperature rises less than 9 degrees in 3 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 35 or 90 seconds.
  • Causes: • Fusing thermistor defective or out of position
    • Fusing lamp open
    • Power supply board defective
  • Code: 543
  • Description: Fusing overheat error (center)
    The fusing temperature is over 230°C for 1 second (detected by the thermistor).
  • Causes: • Fusing thermistor defective
    • Power supply board defective
  • Code: 544
  • Description: Fusing overheat error (center) 2
    The fusing temperature is over 250°C for 1 second (detected by the fusing temperature monitor circuit).
  • Causes: • Fusing thermistor defective
    • Power supply board defective
  • Code: 545
  • Description: Fusing lamp overheat error (center)
    After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 15 consecutive seconds.
  • Causes: • Fusing thermistor defective or out of position
    • Power supply board defective
  • Code: 546
  • Description: Unstable fusing temperature (center)
    The fusing temperature varies 50° C or more within 1 second, and this occurs 2 consecutive times.
  • Causes: • Thermistor defective or out of position
    • Power supply unit defective