Code :
- Code: 823
- Description: Self-diagnostic Error: Network Interface
The network interface board returned an error during the self-diagnostic test.
- Causes: - Network interface board defective
- Controller board defective
- Code: 824
- Description: Self-diagnostic Error: NVRAM
The resident non-volatile RAM returned an error during the self-diagnostic test.
- Causes: - Replace the NVRAM on the controller board
- Replace the controller board
- Code: 826
- Description: Self-diagnostic Error: NVRAM/Optional NVRAM
The NVRAM or optional NVRAM returned an error during the self-diagnostic test.
- Causes: - Replace the NVRAM on the controller board
- Code: 827
- Description: Self-diagnostic Error: RAM
The resident RAM returned a verify error during the self-diagnostic test.
- Causes: - Download controller firmware again
- Code: 828
- Description: Self-diagnostic Error: ROM
The resident read-only memory returned an error during the self-diagnostic test.
- Causes: - Controller board defective
- Download controller firmware again
- Code: 829
- Description: Self-diagnostic Error: Optional RAM
The optional RAM returned an error during the self-diagnostic test
- Causes: - Replace the optional memory board
- Controller board defective
- Code: 838
- Description: Self-diagnostic Error: Clock Generator
A verify error occurred when setting data was read from the clock generator via the I2C bus
- Causes: - Replace the controller board
- Code: 850
- Description: Network I/F Abnormal
NIB interface error.
- Causes: - NIB defective
- Controller board defective