  • Code: 144
  • Description: Communication Error between BICU and SBU
    The BICU board cannot detect the SBU connect signal.
  • Causes: • The flat cable between the BICU board and the SBU has a poor connection • The flat cable between the BICU board and the SBU is damaged • BICU board • SBU
  • Code: 161-01
  • Description: IPU (BICU) error (LSYNC error) (D158/D159)
    Error was detected in the result of the BICU self-check at startup.
  • Causes: • Defective BICU • Bad cable connection between the SBU and the BICU.
  • Code: 161-02
  • Description: IPU (BICU) error (RI response error) (D158/D159)
    Error was detected on access to the RL
  • Causes: • Defective BICU
  • Code: 165
  • Description: Unauthorized copy protection Failed (D158/D159)
    Detected the wrong type of copy data protection unit, or no unit was found when copy protection was turned on, or a problem was detected with the unit at startup.
  • Causes: • Copy data protection unit not attached firmly. • Defective copy data protection unit
  • Code: 195
  • Description: Serial number mismatch
    Checking if the serial number matches.
  • Causes: • Serial numbers (11 digits) do not match.
  • Code: 202
  • Description: Polygon motor error : ON timeout
    When the polygon motor is rotating.
  • Causes: • Defective or disconnected harness to polygon motor • Defective polygon motor • The polygon motor drive pulse is not released correctly.
  • Code: 203
  • Description: Polygon motor error : OFF timeout
    When the polygon motor is OFF.
  • Causes: • Defective or disconnected harness to polygon motor • Defective polygon motor • The polygon motor drive pulse is not released correctly.
  • Code: 204
  • Description: Polygon motor error : PMRDY_N signal error
    When the polygon motor is rotating.
  • Causes: • Defective or disconnected harness to polygon motor • Defective polygon motor