Các lỗi thường gặp

Code :
  • Code: 545
  • Description: Fusing overheat error 3 (center)
    After warmup, the center of the hot roller attained full operating temperature and maintained this temperature for 10 sec. without the hot roller rotating.
  • Causes: • Center hot roller thermistor installed incorrectly, disconnected. • Center hot roller thermistor defective
  • Remedy: 1. Check the hot roller thermistor is set correctly. 2. Replace the hot roller thermistor.
  • Code: 547
  • Description: The zero cross signal is detected for 0.05 seconds three times even though the heater relay is off when turning on the main power.
    • The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door.
  • Causes: • Defective fusing lamp relay • Defective fusing lamp relay circuit • Unstable power supply
  • Remedy: 1. Replace the fusing lamp relay. 2. Check the power supply source.
  • Code: 551
  • Description: Fusing thermistor open (end)
    The temperature of the hot roller remained below 0C for 5 sec. at the end of the hot roller.
  • Causes: • Fusing thermistor out of its position because of incorrect installation • Fusing thermistor disconnected or defective • Power supply not within rated range (15% or more below rating)
  • Remedy: 1. Check the fusing thermistor is set correctly. 2. Replace the fusing thermistor. 3. Check the power supply source.
  • Code: 552
  • Description: Fusing temperature warm-up error (end)
    The fusing temperature did not reach the standby temperature within 20 sec. at the center of the hot roller after the main switch turned on.
  • Causes: • Fusing thermistor defective or out of position • Fusing lamp disconnected • Thermistor defective • Fusing lamp defective
  • Remedy: 1. Check the fusing thermistor is set correctly. 2. Check the fusing lamp is connected correctly. 3. Replace the fusing thermistor. 4. Replace the fusing lamp.
  • Code: 553
  • Description: Fusing overheat error 1 (end)
    The fusing thermistor detected a fusing temperature over 230°C for 5 sec. at the center of the hot roller.
  • Causes: • TRIAC short on PSU (PSU defective) • BCU board defective • Fusing thermistor defective
  • Remedy: 1. Replace the PSU. 2. Replace the BCU board. 3. Replace the thermistor.
  • Code: 554
  • Description: Fusing overheat error 2 (end)
    A fusing temperature over 250°C is detected at the center of the hot roller by the fusing temperature monitor circuit in the BCU board. The power was interrupted for more than 0.3 sec.
  • Causes: • TRIAC short on PSU (PSU defective) • BCU board defective • Fusing thermistor defective • Power supply voltage unstable
  • Remedy: 1. Replace the PSU. 2. Replace the BCU board. 3. Replace the thermistor. 4. Check the power supply source.
  • Code: 555
  • Description: Fusing overheat error 3 (end)
    After warmup, the center of the hot roller attained full operating temperature and maintained this temperature for 10 sec. without the hot roller rotating.
  • Causes: • Center hot roller thermistor installed incorrectly, disconnected. • Center hot roller thermistor defective
  • Remedy: 1. Check the hot roller thermistor is set correctly. 2. Replace the hot roller thermistor.
  • Code: 557
  • Description: Zero cross waveform signal error
    The waveform of the zero cross signal was detected out of range.
  • Causes: • Electrical noise on the power supply line
  • Remedy: Check the power supply source.