Description: Fusing High Temperature Detection (hardware) (Non-Contact thermistor High Temperature Error) In the event of an error
Causes: • Triac defective (short-circuit) • Engine controller defective • Heating central thermopile defective • Fusing control software: out of control
Remedy: • Attach the new fusing unit, then run SP-5-810-002. • If the triac is defective, replace the AC power supply board. • If necessary, replace the BCU or the Fusing central NC sensor.
Description: Fusing Central Heater Continuously Heat After waiting for full power for more than specified seconds continuously, not detected for specified seconds. • Definition of heater full power Continuously heating rate set point (maximum heating rate) • Measurement start point After reload (after heater extinguished, after rotation complete) below the standby temperature (target temperature), measurement starts after a heater heat-up request is issued. • Measurement stop condition Rotation started due to a print signal during measurement or other. • Maximum heat-up Duty (SP interlinked value) 0% is excluded.
Causes: • Thermistor deformation/float • Heater disconnection • After excessive temperature rise prevention unit operates
Remedy: • Replace the thermistor. • Replace the fusing lamp. • Replace the fusing unit.
Remedy: • Turn the main power supply switch OFF/ON • If the fusing relay is damaged, replace the PSU. • Check the connection between PSU and control board, and replace harness and board if necessary.
Remedy: • Turn the main power supply switch OFF/ON. • If the fusing relay is damaged, replace the PSU. • Check the connection between PSU and control board, and replace harness and board if necessary. • If the PSU fuse (24VS) blows out, replace the fuse.
Description: Zero cross Error (low-frequency error) In the event of an error
Causes: Frequency instability of commercial power line
Remedy: • Turn the main power supply switch OFF/ON. • Check the power source. • Check the connection between PSU and control board, and replace harness and board if necessary.
Description: Fusing Edge Thermopile Disconnection When the fusing edge thermopile detects a predetermined temperature or less for specified seconds consecutively.