Description: GASBU reset error
The serial communication does not work.
Causes: • Defective SBU • Defective detection circuit on the BICU • Defective harness
Code: 144-004
Description: VERSION error
The serial communication does not work.
Causes: • Defective SBU • Defective detection circuit on the BICU • Defective harness
Code: 145
Description: Scanner adjustment error
During the SBU adjustment, the machine detects that the white level read from the white plate or paper is out of range. (SP4015)
Causes: • Exposure lamp defective • Dirty white plate • Incorrect position or width of white plate scanning (SP4015) • BICU board defective • SBU board defective
Code: 161
Description: IPU error
The error result of self-diagnostic by the ASIC on the IPU is detected.
Causes: • Defective IPU • Defective connection between IPU and SBU
Code: 165
Description: Copy Data Security Unit error
The copy data security board is not detected when the copy data security function is set "ON" with the initial setting.
A device check error occurs when the copy data security function is set to "ON" with the initial setting.
Causes: • Incorrect installation of the copy data security board • Defective copy data security board
Code: 202
Description: Polygon motor error 1: ON timeout
The polygon mirror motor does not reach the targeted operating speed within 10 sec. after turning on or changing speed
Causes:
Code: 203
Description: Polygon motor error 2: OFF timeout
The polygon mirror motor does not leave the READY status within 3 sec. after the polygon motor switched off.
Causes:
Code: 204
Description: Polygon motor error 3: XSCRDY signal error
The SCRDY_N signal remains HIGH for 200 ms while the LD unit is firing.