Causes: • The machine detects that the optional ICIB is not installed or is faulty even if "Unauthorized Copy Protection" in User Tools is enabled. • When the machine is switched on or recovers from the evergy saver mode, it detects that the installed optional ICIB is faulty. • ICIB nlot attached correctly • Defective ICIB
Remedy: • Connect the ICIB correctly • Replace the ICIB
Causes: Comparison of the product identification code in the machine serial number (11 digits). The product identification code in the machine serial number (11 digits) does not match.
Description: FGATE*1 : Does not turn ON. (*1)FGATE: Signals used between the controller and the engine in order to send the information about the sub scan length of the page to be printed.
Causes: GPIO*2 has not been asserted, although the specified time (200 ms) elapsed after setting JOB to be started and reaching the FGAT assert time. Control Board (*2)GPIO: A type of input/output terminal
Description: FGATE*1: Does not turn OFF. (*1)FGATE: Signals used between the controller and the engine in order to send the information about the sub scan length of the page to be printed.
Causes: GPIO*2 has not been negated, although the specified time (200 ms) elapsed after detecting GPIO*assert and then reaching the expected FGATE negate time. * This is an I/O pin. Such I/O pins can be used for a variety of applications, depending on the setting. (*2)GPIO: A type of input/output terminal
Causes: • When the Engine Board could not read the Unique ID of the Writing ASIC properly when starting this machine. • When an Error bit occurred in the communication between the Engine Board and the Writing ASIC. The unique ID of the write ASIC was not read normally.
Remedy: • Turn the main power OFF and then ON. • Engine Board