Description: Printer setting error
The IPU does not respond with the settings that are required to start image processing by the printer.
Causes: • Software defective
Code: 955
Description: Memory setting error
The IPU does not respond with the settings that are required to start image processing using the memory.
Causes: • Software defective
Code: 980
Description: NVRAM value error
A critical SP code setting is not within range. If the machine is allowed to operate in this condition, this could lead to toner overflow and damage the machine.
Causes:
Code: 984
Description: Print image data transfer error
The image transfer from the controller to the engine via the PCI bus does not end within 15 s after starting.
Causes: • Controller board defective • BICU defective • Connectors between BICU and controller loose or defective
Code: 985
Description: Scanner image data transfer error
The image transfer from the engine to the controller via the PCI bus does not end within 3 s after starting.
Causes: • Controller board defective • BICU defective • Connectors between BICU and controller loose or defective • SIB defective
Code: 986
Description: Software write parameter setting error
An unstable area at the storage destination in the settings table is set NULL for the parameter received by the write module.
Causes: • Software defective
Code: 990
Description: Software error 1
The software performs an unexpected function and the program cannot continue.
Causes: • Software defective, re-boot
Code: 991
Description: Software error 2
The software performs an unexpected function. However, unlike SC990, recovery processing allows the program to continue.