Các lỗi thường gặp

Code :
  • Code: SC672-10
  • Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established.
  • Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
  • Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
  • Code: SC672-11
  • Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup.
  • Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
  • Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
  • Code: SC672-12
  • Description: Controller start up error Communication with controller was interrupted after a normal startup.
  • Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
  • Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
  • Code: SC672-13
  • Description: Controller start up error The operation panel detected that the controller is down.
  • Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
  • Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
  • Code: SC672-99
  • Description: Controller start up error The operation panel software ended abnormally.
  • Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
  • Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
  • Code: SC682
  • Description: PCU: ID Chip Communication Error. Received an error notification during EEPROM communication and does not resume after 3 retries.
  • Causes: • Device ID date error • Mu sesnsor / EEPROM defective • Electrical noise • PCU is not set properly.
  • Remedy: • Turn the power off/on. • Replace the PCU.
  • Code: SC682-36
  • Description: PCU: Verify Error Received a error notification during EEPROM communication and does not resume after 2 retries.
  • Causes: • Device ID date error • Mu sesnsor / EEPROM defective • Electrical noise • PCU is not set properly.
  • Remedy: • Turn the power off/on. • Replace the PCU.
  • Code: SC687-00
  • Description: PER Not Received Error Unable to receive the PER command from the controller.
  • Causes: Communication error
  • Remedy: • Turn the power off/on.