Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established.
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Code: SC672-11
Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup.
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Code: SC672-12
Description: Controller start up error Communication with controller was interrupted after a normal startup.
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Code: SC672-13
Description: Controller start up error The operation panel detected that the controller is down.
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Code: SC672-99
Description: Controller start up error The operation panel software ended abnormally.
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Code: SC682
Description: PCU: ID Chip Communication Error. Received an error notification during EEPROM communication and does not resume after 3 retries.
Causes: • Device ID date error • Mu sesnsor / EEPROM defective • Electrical noise • PCU is not set properly.
Remedy: • Turn the power off/on. • Replace the PCU.
Code: SC682-36
Description: PCU: Verify Error Received a error notification during EEPROM communication and does not resume after 2 retries.
Causes: • Device ID date error • Mu sesnsor / EEPROM defective • Electrical noise • PCU is not set properly.
Remedy: • Turn the power off/on. • Replace the PCU.
Code: SC687-00
Description: PER Not Received Error Unable to receive the PER command from the controller.