Description: Edge NC Sensor Short-circuit AD value: 0-13 (FB voltage: 0.000V-0.041V) is detected for specified seconds continuously. Detection period: 100 ms, detection frequency: 10 times or more.
Remedy: • Replace the NC sensor. • Reset the connector. • Replace the connector. • Replace the fusing unit.
Code: SC552-02
Description: Fusing Edge Thermopile Does Not Reload When the fusing edge thermopile does not reach a predetermined temperature for specified seconds consecutively.
Causes: • Thermopile lens dirt • Thermopile modification, float • Outside input voltage guarantee • After excessive temperature rise prevention unit operation
Remedy: • Replace the thermopile. • Make sure that the input voltage is within acceptable limits. • Replace the fusing unit.
Code: SC552-03
Description: Fusing Edge Thermopile Does Not Reload Heating edge reload permission temperature not reached after heater 1 ON for specified seconds.
Causes: • Thermopile lens dirt • Thermopile modification, float • Outside input voltage guarantee • After excessive temperature rise prevention unit operation
Remedy: • Replace the thermopile. • Make sure that the input voltage is within acceptable limits. • Replace the fusing unit.
Code: SC552-05
Description: Fusing Edge Thermopile Does Not Reload (Low Voltage) When the fusing edge thermopile does not reach a predetermined temperature for specified seconds consecutively.
Causes: • Thermopile lens dirt • Thermopile modification, float • Outside input voltage guarantee • After excessive temperature rise prevention unit operation
Remedy: • Replace the thermopile. • Make sure that the input voltage is within acceptable limits. • Replace the fusing unit.
Code: SC552-06
Description: Fusing Edge Thermopile Does Not Reload (Low Voltage) When the fusing edge thermopile does not reach the permission temperature of heat edge reloading for specified seconds continuously.
Causes: • Thermopile lens dirt • Thermopile modification, float • Outside input voltage guarantee • After excessive temperature rise prevention unit operation
Remedy: • Replace the thermopile. • Make sure that the input voltage is within acceptable limits. • Replace the fusing unit.
Code: SC553-00
Description: Fusing End Thermopile High Temperature Detection (software) Above a predetermined temperature detected for specified seconds continuously. Detection period: 100ms, detection count: 10 times or more.