Mã lỗi Ricoh Aficio MP6054 — Trang 19/40

Code: SC672-10

Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established.
Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.

Code: SC672-11

Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup.
Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.

Code: SC672-12

Description: Controller start up error Communication with controller was interrupted after a normal startup.
Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.

Code: SC672-13

Description: Controller start up error The operation panel detected that the controller is down.
Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.

Code: SC672-99

Description: Controller start up error The operation panel software ended abnormally.
Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.

Code: SC682

Description: PCU: ID Chip Communication Error. Received an error notification during EEPROM communication and does not resume after 3 retries.
Causes: • Device ID date error • Mu sesnsor / EEPROM defective • Electrical noise • PCU is not set properly.
Remedy: • Turn the power off/on. • Replace the PCU.

Code: SC682-36

Description: PCU: Verify Error Received a error notification during EEPROM communication and does not resume after 2 retries.
Causes: • Device ID date error • Mu sesnsor / EEPROM defective • Electrical noise • PCU is not set properly.
Remedy: • Turn the power off/on. • Replace the PCU.

Code: SC687-00

Description: PER Not Received Error Unable to receive the PER command from the controller.
Causes: Communication error
Remedy: • Turn the power off/on.