Description: ASIC (Taurus) memory error
The memory check error of ASIC (Taurus) is detected when a machine turns on or recovers from the energy saver mode.
Causes: • Defective IPU (Taurus memory) • Unusual power source
Description: Copy Data Security Unit error
• The copy data security board is not detected when the copy data security function is set "ON" with the initial setting. • A device check error occurs when the copy data security function is set "ON" with the initial setting.
Causes: • Incorrect installation of the copy data security board • Defective copy data security board
Description: Maintenance unit home position error
• The maintenance unit sensor does not get "OFF" signal after the maintenance unit motor has rotated. • The maintenance unit sensor does not get "ON" signal even the maintenance unit motor has rotated for certain time when it is assumed that the maintenance unit has to return to the home position.
Causes: • Defective maintenance unit home position sensor • Defective maintenance unit drive motor
Description: Tank full lever error
• The position of the tank full lever does not stay at the tank full position after ink initialization or air releasing. • The position of the tank full lever is not detected at ink suction.
Causes: • Defective tank full sensor • Tank full lever bent or broken • Incorrect ink suction