Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio MPC2050 — Trang 10/23

Code: 535

Description: Controller box fan error
The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective controller box fan • Disconnected or defective harness • Defective BCU
Remedy: 1. Check or replace the harness. 2. Replace the controller box fan. 3. Replace the BCU.

Code: 536

Description: Junction gate solenoid fan error
The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective junction gate solenoid fan • Disconnected or defective harness • Defective BCU
Remedy: 1. Check or replace the harness. 2. Replace the junction gate solenoid fan. 3. Replace the BCU.

Code: 540

Description: Fusing/Paper exit motor error
The BCU receives the lock signal 2.0 seconds after turning on the fusing/paper exit motor.
Causes: • Motor overload • Defective fusing/paper exit motor • Defective or disconnected connection for the fusing/paper exit motor
Remedy: 1. Replace the fusing/paper exit motor. 2. Check or replace connector and harness for the fusing/paper exit motor.

Code: 541

Description: Heating roller error 1 The temperature detected by the thermopile does not reach 0°C for 6 seconds.
Causes: • Loose connection of the thermopile • Defective thermopile
Remedy: 1. Check that the thermopile is firmly connected. 2. Replace the thermopile.

Code: 542

Description: Heating roller warm-up error 1
• After the main switch is turned on or the cover is closed, the increment of the heating roller temperature per 10 seconds is 30°C or less. If this condition is detected five times consecutively, SC 542 is defined. • The heating roller temperature does not reach 100°C for 15 seconds after the heating lamp on. • The heating roller temperature does not reach the ready temperature while 60 seconds after the heating lamp on. • The center temperature of the heating roller does not reach the ready temperature for 30 seconds after the edge temperature of the heating roller has reached the ready temperature
Causes: • Dirty or defective thermopile • Defective thermopile. • Trash on the surface of the thermopile lens. • Defected thermistor. • Input voltage is over guaranteed value • Defective heating roller lamp
Remedy: 1. Check if the thermopile is firmly connected. 2. Clean the surface of the thermopile lens. 3. Test the conductance for the thermopile and the heating roller 4. Replace the thermopile. 5. Replace the heating roller lamp.

Code: 543

Description: Heating roller fusing lamp overheat 1 (software error)
The detected fusing temperature stays at 230°C for 1 second.
Causes: • Defective PSU • Defective BCU
Remedy: 1. Replace the PSU. 2. Replace the BCU.

Code: 544

Description: Heating roller fusing lamp overheat 1 (hardware error)
During stand-by mode or a print job, the detected heating roller temperature reaches 250 °C.
Causes: • Defective PSU • Defective BCU • Defective heating roller thermistor (end) • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the BCU. 3. Replace the heating roller thermistor (end).

Code: 545

Description: Heating roller fusing lamp consecutive full power 1
When the fusing unit is not running in the ready condition, the heating roller fusing lamp keeps on full power for 8 seconds.
Causes: • Broken heating roller thermostat • Broken heating roller fusing lamp
Remedy: 1. Replace the heating roller thermistor. 2. Replace the heating roller fusing lamp.