Description: Heating roller warm-up error 1 • After the main switch is turned on or the cover is closed, the increment of the heating roller temperature per 10 seconds is 30°C or less. If this condition is detected five times consecutively, SC 542 is defined. • The heating roller temperature does not reach 100°C for 15 seconds after the heating lamp on. • The heating roller temperature does not reach the ready temperature while 60 seconds after the heating lamp on. • The center temperature of the heating roller does not reach the ready temperature for 30 seconds after the edge temperature of the heating roller has reached the ready temperature
Causes: • Dirty or defective thermopile • Defective thermopile. • Trash on the surface of the thermopile lens. • Defected thermistor. • Input voltage is over guaranteed value • Defective heating roller lamp
Remedy: 1. Check if the thermopile is firmly connected. 2. Clean the surface of the thermopile lens. 3. Test the conductance for the thermopile and the heating roller 4. Replace the thermopile. 5. Replace the heating roller lamp.
Description: Heating roller fusing lamp overheat 1 (hardware error) During stand-by mode or a print job, the detected heating roller temperature reaches 250 °C.
Causes: • Defective PSU • Defective BCU • Defective heating roller thermistor (end) • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the BCU. 3. Replace the heating roller thermistor (end).
Description: Heating roller fusing lamp consecutive full power 1 When the fusing unit is not running in the ready condition, the heating roller fusing lamp keeps on full power for 8 seconds.