Description: TD sensor (Vt high) error 1: M The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCU defective. Defective TD sensor.
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
Code: 362
Description: TD sensor (Vt high) error 1: C The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCU defective. Defective TD sensor.
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
Code: 363
Description: TD sensor (Vt high) error 1: Y The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCU defective. Defective TD sensor.
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
Code: 364
Description: TD sensor (Vt high) error 2: K The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) for 10 counts.
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
Code: 365
Description: TD sensor (Vt high) error 2: M The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) for 10 counts.
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
Code: 366
Description: TD sensor (Vt high) error 2: C The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) for 10 counts.
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
Code: 367
Description: TD sensor (Vt high) error 2: Y The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) for 10 counts.
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
Code: 372
Description: TD sensor adjustment error: K During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
Causes: Heat seal not removed from a new developer pack. TD harness sensor disconnected, loose or defective. TD sensor defective. Harness between TD sensor and drawer disconnected, defective.
Remedy: 1. Remove the heat seal from each PCU. 2. Replace the defective PCU.