Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio MPC2550 — Trang 3/23

Code: 226

Description: Laser synchronizing detection error: start position [C]
The laser synchronizing detection signal for the start position of the LDB [K], [Y], [M], [C] is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector. Defective LDB. Defective BICU.
Remedy: 1. Check the connectors. 2. Replace the laser unit. 3. Replace the i-controller. 4. Replace the BCU.

Code: 230

Description: FGATE ON error: K
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [K].
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.

Code: 231

Description: FGATE OFF error: K
• The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and BICU. • Defective BICU
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.

Code: 232

Description: FGATE ON error: Y
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [Y].
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.

Code: 233

Description: FGATE OFF error: YT
he PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [Y]. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.

Code: 234

Description: FGATE ON error: M
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [M].
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.

Code: 235

Description: FGATE OFF error: M
The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [M]. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.

Code: 236

Description: FGATE ON error: C
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [C].
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.