Các lỗi thường gặp

Code :
  • Code: 165
  • Description: Copy Data Security Unit error
    • The copy data security board is not detected when the copy data security function is set "ON" with the initial setting. • A device check error occurs when the copy data security function is set "ON" with the initial setting.
  • Causes: • Incorrect installation of the copy data security board • Defective copy data security board
  • Remedy: 1. Reinstall the copy data security board. 2. Replace the copy data security board.
  • Code: 195
  • Description: Serial Number Mismatch
    • Serial number stored in the memory does not have the correct code.
  • Causes: • NVRAM defective • BICU replaced without original NVRAM
  • Remedy: 1. Reinstall the original NVRAM in the replaced BCU. 2. Turn off and on the main power switch of the copier if a new NVRAM is installed in the BCU.
  • Code: 202
  • Description: Polygon motor error 1: ON timeout
    The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
  • Causes: • Defective or disconnected harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor.
  • Remedy: 1. Replace the polygon motor. 2. Replace the laser unit. 3. Replace the harness. 4. Replace the IPU board. 5. Replace the BCU.
  • Code: 203
  • Description: Polygon motor error 2: OFF timeout
    The polygon mirror motor does leave the READY status within 3 seconds after the polygon motor switches off.
  • Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor
  • Remedy: 1. Check or replace the harness. 2. Replace the polygon motor. 3. Replace the IPU board. 4. Replace the BCU.
  • Code: 204
  • Description: Polygon motor error 3: XSCRDY signal error
    The SCRDY_N signal goes HIGH (inactive) while the laser diode is firing.
  • Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor • Defective polygon motor driver board
  • Remedy: 1. Check or replace the harness. 2. Replace the polygon motor. 3. Replace the IPU board. 4. Replace the BCU.
  • Code: 220
  • Description: Laser synchronizing detection error: start position [K]
    The laser synchronizing detection signal for the start position of the LDB [K], [Y], [M], [C] is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
  • Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector. Defective LDB. Defective BICU.
  • Remedy: 1. Check the connectors. 2. Replace the laser unit. 3. Replace the IPU board. 4. Replace the BCU.
  • Code: 222
  • Description: Laser synchronizing detection error: start position [Y]
    The laser synchronizing detection signal for the start position of the LDB [K], [Y], [M], [C] is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
  • Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector. Defective LDB. Defective BICU.
  • Remedy: 1. Check the connectors. 2. Replace the laser unit. 3. Replace the IPU board. 4. Replace the BCU.
  • Code: 224
  • Description: Laser synchronizing detection error: start position [M]
    The laser synchronizing detection signal for the start position of the LDB [K], [Y], [M], [C] is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
  • Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector. Defective LDB. Defective BICU.
  • Remedy: 1. Check the connectors. 2. Replace the laser unit. 3. Replace the IPU board. 4. Replace the BCU.
 < 1 2 3 4 5 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục