Các lỗi thường gặp

Code :
  • Code: 582
  • Description: IH inverter current error at power on
    The output current from the IH inverter does not reach the proper value when the IH inverter turns on.
  • Causes: • Disconnected power input terminal 1 and 2 • Defective IH inverter • Defective IH coil unit • Defective fusing unit
  • Remedy: 1. Check the power input terminals 1 and 2. 2. Replace the IH inverter. 3. Replace the IH coil unit. 4. Replace the fusing unit.
  • Code: 585
  • Description: IH coil unit full power (1250W) error
    The IH coil unit full power (1250W) continues for 200 seconds or more.
  • Causes: • Defective IH inverter • Defective BICU • Defective IOB • Broken connection between IH inverter and IOB • Defective thermopile
  • Remedy: 1. Replace the IH inverter. 2. Replace the BICU. 3. Replace the IOB. 4. Check the connection between IH inverter and IOB. 5. Replace the thermopile.
  • Code: 610
  • Description: Mechanical counter error: K
    This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".
  • Causes: • Disconnected mechanical counter • Defective mechanical counter
  • Remedy: Check or replace the mechanical counter.
  • Code: 611
  • Description: Mechanical counter error: FC
    This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".
  • Causes: • Disconnected mechanical counter • Defective mechanical counter
  • Remedy: Check or replace the mechanical counter.
  • Code: 620
  • Description: ARDF communication error
    After the ARDF is detected, the break signal occurs or communication timeout occurs.
  • Causes: • Incorrect installation of ARDF • ARDF defective • BICU board defective • External noise
  • Remedy: 1. Check the cable connection of the ARDF. 2. Shut out the external noise. 3. Replace the ARDF. 4. Replace the BICU board.
  • Code: 621
  • Description: Finisher communication error
    While the IOB communicates with an optional unit, an SC code is displayed if one of following conditions occurs. • The IOB receives the break signal which is generated by the peripherals only just after the main switch is turned on. • When the IOB does not receive an OK signal from a peripheral 100ms after sending a command to it. The IOB resends the command. The IOB does not receive an OK signal after sending the command 3 times.
  • Causes: • Cable problems • IOB problems • BICU problems • PSU problems in the machine • Main board problems in the peripherals
  • Remedy: 1. Check if the cables of peripherals are correctly connected. 2. Replace the PSU if no power is supplied to peripherals. 3. Replace the IOB or main board of peripherals. 4. Replace the BICU.
  • Code: 622
  • Description: Paper tray unit communication error
    While the IOB communicates with an optional unit, an SC code is displayed if one of following conditions occurs. • The IOB receives the break signal which is generated by the peripherals only just after the main switch is turned on. • When the IOB does not receive an OK signal from a peripheral 100ms after sending a command to it. The IOB resends the command. The IOB does not receive an OK signal after sending the command 3 times.
  • Causes: • Cable problems • IOB problems • BICU problems • PSU problems in the machine • Main board problems in the peripherals
  • Remedy: 1. Check if the cables of peripherals are correctly connected. 2. Replace the PSU if no power is supplied to peripherals. 3. Replace the IOB or main board of peripherals. 4. Replace the BICU.
  • Code: 623
  • Description: 2nd Paper Bank communication error
    This SC is not issued for this machine. When a communication error signal between the 1st paper bank and 2nd paper bank is received.
  • Causes: • Loose connector
  • Remedy: Check the connection between the main machine and paper feed unit.