Description: Heating roller fusing lamp consecutive full power 1 When the fusing unit is not running in the ready condition, the heating roller fusing lamp keeps on full power for 8 seconds.
Causes: • Broken heating roller fusing lamp
Remedy: 1. Replace the heating roller fusing lamp. 2. Replace the PSU.
Code: 547
Description: Zero cross error • The zero cross signal is detected three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Remedy: 1. Check the power supply source. 2. Replace the PSU
Code: 551
Description: Heating roller thermistor error The temperature at the end of the heating roller measured by the heating roller thermistor does not reach 0°C for 7 seconds.
Remedy: 1. Check that the heating roller thermistor is firmly connected. 2. Replace the heating roller thermistor.
Code: 552
Description: Heating roller warm-up error 2 • The heating roller temperature does not reach 80°C for 20 seconds. • The temperature at the end of the heating roller does not reach the ready temperature for 89 seconds .
Causes: • Defective heating roller thermistor
Remedy: 1. Check if the heating roller thermistor is firmly connected.
Code: 553
Description: Heating roller fusing lamp overheat 2 (software error) The temperature detected by the heating roller thermistor stays at 230°C or more for 1 second.
Remedy: 1. Replace the PSU. 2. Replace the IPU. 3. Replace the BCU.
Code: 554
Description: Heating roller fusing lamp overheat 2 (hardware error) The temperature detected by the heating roller thermistor reaches 250°C or more.
Causes: • Defective PSU • Defective IPU • Defective BCU • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the IPU. 3. Replace the BCU.
Code: 555
Description: Heating roller lamp consecutive full power 2 The heating roller-fusing lamp stays ON for 15 seconds or more while the fusing unit is in the ready condition.
Causes: • Broken heating roller fusing lamp
Remedy: 1. Replace the heating roller fusing lamp. 2. Replace the PSU.
Code: 557
Description: Zero cross frequency error When the zero cross signal is 66 or more and it is detected 10 times or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs.
Causes: • Noise (High frequency) • Defective PSU
Remedy: 1. Check the power supply source. 2. Replace the PSU.