Code: 243

Description: LD error: C
The BICU detects LDB error a few times consecutively when LDB unit turns on after LDB initialization.
Causes: Worn-out LD. Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BICU.

Code: 285

Description: Line position adjustment (MUSIC) error
Line position adjustment fails four consecutive times.
Causes: • Pattern sampling error ( insufficient image density ) • Defective ID sensors for the line position adjustment • Defective image transfer belt unit • Defective PCU(s) • Defective laser optics housing unit
Remedy: 1. Check and reinstall the image transfer belt unit and PCUs. 2. Check if each toner bottle has enough toner. 3. Replace the ID sensor. 4. Replace the image transfer belt unit. 5. Replace the PCU(s). 6. Replace the laser optics housing unit.

Code: 300

Description: AC charge output error [K]
The measured voltage is not proper when BICU measures the charge output for each color.
Causes: Disconnected or broken high voltage cable. Defective or not installed PCU. Defective high voltage power supply.
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected color. 3. Replace the high voltage power supply.

Code: 301

Description: AC charge output error [M]
The measured voltage is not proper when BICU measures the charge output for each color.
Causes: Disconnected or broken high voltage cable. Defective or not installed PCU. Defective high voltage power supply.
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected color. 3. Replace the high voltage power supply.

Code: 302

Description: AC charge output error [C]
The measured voltage is not proper when BICU measures the charge output for each color.
Causes: Disconnected or broken high voltage cable. Defective or not installed PCU. Defective high voltage power supply.
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected color. 3. Replace the high voltage power supply.

Code: 303

Description: AC charge output error [Y]
The measured voltage is not proper when BICU measures the charge output for each color.
Causes: Disconnected or broken high voltage cable. Defective or not installed PCU. Defective high voltage power supply.
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected color. 3. Replace the high voltage power supply.

Code: 360

Description: TD sensor (Vt high) error 1: K
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCU defective. Defective TD sensor.
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.

Code: 361

Description: TD sensor (Vt high) error 1: M
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCU defective. Defective TD sensor.
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.