Các lỗi thường gặp

Code :
  • Code: 231
  • Description: FGATE OFF error: K
    • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K]. • The PFGATE ON signal still asserts when the next job starts.
  • Causes: • Defective ASIC (Lupus) • Poor connection between controller and BCU. • Defective BCU
  • Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
  • Code: 232
  • Description: FGATE ON error: Y
    The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [Y].
  • Causes: • Defective ASIC (Lupus) • Poor connection between controller and BCU. • Defective BCU
  • Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
  • Code: 233
  • Description: FGATE OFF error: Y
    • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [Y]. • The PFGATE ON signal still asserts when the next job starts.
  • Causes: • Defective ASIC (Lupus) • Poor connection between controller and BCU. • Defective BCU
  • Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
  • Code: 234
  • Description: FGATE ON error: M
    The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [M].
  • Causes: • Defective ASIC (Lupus) • Poor connection between controller and BCU. • Defective BCU
  • Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
  • Code: 235
  • Description: FGATE OFF error: M
    • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [M]. • The PFGATE ON signal still asserts when the next job starts.
  • Causes: • Defective ASIC (Lupus) • Poor connection between controller and BCU. • Defective BCU
  • Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
  • Code: 236
  • Description: FGATE ON error: C
    The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [C].
  • Causes: • Defective ASIC (Lupus) • Poor connection between controller and BCU. • Defective BCU
  • Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
  • Code: 237
  • Description: FGATE OFF error: C
    • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [C]. • The PFGATE ON signal still asserts when the next job starts.
  • Causes: • Defective ASIC (Lupus) • Poor connection between controller and BCU. • Defective BCU
  • Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
  • Code: 240
  • Description: LD error: K
    The BCU detects LDB error a few times consecutively when LDB unit turns on after LDB initialization.
  • Causes: • Worn-out LD • Disconnected or broken harness of the LD
  • Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BCU.