Các lỗi thường gặp

Code :
  • Code: 302
  • Description: AC charge output error [C]
    The measured voltage is not proper when BICU measures the charge output for each color.
  • Causes: Disconnected or broken high voltage cable. Defective or not installed PCU. Defective high voltage power supply.
  • Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected color. 3. Replace the high voltage power supply.
  • Code: 303
  • Description: AC charge output error [Y]
    The measured voltage is not proper when BICU measures the charge output for each color.
  • Causes: Disconnected or broken high voltage cable. Defective or not installed PCU. Defective high voltage power supply.
  • Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected color. 3. Replace the high voltage power supply.
  • Code: 360
  • Description: TD sensor (Vt high) error 1: K
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
  • Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCU defective. Defective TD sensor.
  • Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
  • Code: 361
  • Description: TD sensor (Vt high) error 1: M
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
  • Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCU defective. Defective TD sensor.
  • Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
  • Code: 362
  • Description: TD sensor (Vt high) error 1: C
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
  • Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCU defective. Defective TD sensor.
  • Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
  • Code: 363
  • Description: TD sensor (Vt high) error 1: Y
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
  • Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCU defective. Defective TD sensor.
  • Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
  • Code: 364
  • Description: TD sensor (Vt high) error 2: K
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) for 10 counts.
  • Causes: TD sensor harness disconnected, loose, defective. A drawer connector disconnected, loose, defective. TD sensor defectiver.
  • Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
  • Code: 365
  • Description: TD sensor (Vt high) error 2: M
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) for 10 counts.
  • Causes: TD sensor harness disconnected, loose, defective. A drawer connector disconnected, loose, defective. TD sensor defectiver.
  • Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.