Code: 555

Description: Heating roller lamp consecutive full power 2 The heating roller-fusing lamp stays ON for 15 seconds or more while the fusing unit is in the ready condition.
Causes: • Broken heating roller fusing lamp
Remedy: • Replace the heating roller fusing lamp. • Replace the PSU.

Code: 557

Description: Zero cross frequency error When the zero cross signal is 66 or more and it is detected 10 times or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs.
Causes: • Noise (High frequency) • Defective PSU
Remedy: • Check the power supply source. • Replace the PSU.

Code: 559

Description: Consecutive fusing jam The paper jam counter for the fusing unit reaches 3 times. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when SP1159-001 is set to "1" (default "0").
Causes: • Paper jam in the fusing unit.
Remedy: • Remove the paper that is jammed in the fusing unit. ] • Then make sure that the fusing unit is clean and has no obstacles in the paper feed path.

Code: 561

Description: Pressure roller thermistor error The temperature detected by the pressure roller thermistor does not reach 0 °C for 20 seconds.
Causes: • Loose connection of the pressure roller thermistor • Defective thermopile • Defective pressure roller thermistor
Remedy: • Check if the pressure roller thermistor is firmly connected. • Replace the thermopile. • Replace the pressure roller thermistor.

Code: 563

Description: Pressure roller overheat (software error) The temperature detected by the pressure roller thermistor stays at 230°C or more for 1 second.
Causes: • Defective PSU • Defective IPU • Defective BCU
Remedy: • Replace the PSU. • Replace the IPU. • Replace the BCU.

Code: 564

Description: Pressure roller overheat (hardware error) The temperature detected by the pressure roller thermistor detects 250°C or more.
Causes: • Defective PSU • Defective IPU • Defective BCU • Defective fusing control system
Remedy: • Replace the thermistor. • Replace the PSU. • Replace the IPU. • Replace the BCU.

Code: 565

Description: Pressure roller fusing lamp consecutive full power When the fusing unit is not running in the ready condition, the pressure roller fusing lamp keeps ON full power for 300 seconds or more.
Causes: • Broken pressure roller fusing lamp • Defective pressure roller thermistor
Remedy: • Replace the pressure roller lamp. • Replace the pressure roller thermistor. • Replace the PSU.

Code: 620

Description: ARDF communication error After the ARDF is detected, the break signal occurs or communication timeout occurs.
Causes: • Incorrect installation of ARDF • ARDF defective • IPU defective
Remedy: • Check the cable connection of the ARDF. • Replace the ARDF. • Replace the IPU.