Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio MPC4501 — Trang 5/26

Code: 231

Description: FGATE OFF error: K
• The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and BICU. • Defective BICU
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.

Code: 232

Description: FGATE ON error: Y
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [Y].
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.

Code: 233

Description: FGATE OFF error: YT
he PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [Y]. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.

Code: 234

Description: FGATE ON error: M
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [M].
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.

Code: 235

Description: FGATE OFF error: M
The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [M]. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.

Code: 236

Description: FGATE ON error: C
The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [C].
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.

Code: 237

Description: FGATE OFF error: C
The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [C]. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective ASIC (Lupus). Poor connection between controller and BICU. Defective BICU.
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.

Code: 240

Description: LD error: Bk
The BICU detects LDB error a few times consecutively when LDB unit turns on after LDB initialization.
Causes: Worn-out LD. Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BICU.