Description: Copy Data Security Unit error • The copy data security board is not detected when the copy data security function is set "ON" with the initial setting. • A device check error occurs when the copy data security function is set "ON" with the initial setting.
Causes: • Incorrect installation of the copy data security board • Defective copy data security board
Remedy: 1. Reinstall the copy data security board. 2. Replace the copy data security board.
Description: Polygon motor error 1: ON timeout The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
Causes: • Defective or disconnected harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor.
Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the IPU.
Description: Polygon motor error 2: OFF timeout The polygon mirror motor does leave the READY status within 3 seconds after the polygon motor switches off.
Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor
Remedy: 1. Check or replace the harness. 2. Replace the polygon motor. 3. Replace the IPU.
Description: Laser synchronizing detection error: end position [K] The laser synchronizing detection signal for the end position of LDB [K], [C], [M], [Y] is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: • Disconnected or defective harness to synchronizing detector for end position • Defective synchronizing detector board • Defective LD board or driver • Defective IPU
Remedy: 1. Check the connectors. 2. Replace the harness of the LD board. 3. Replace the laser optics housing unit. 4. Replace the IPU.
Description: Laser synchronizing detection error: end position [C] The laser synchronizing detection signal for the end position of LDB [K], [C], [M], [Y] is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: • Disconnected or defective harness to synchronizing detector for end position • Defective synchronizing detector board • Defective LD board or driver • Defective IPU
Remedy: 1. Check the connectors. 2. Replace the harness of the LD board. 3. Replace the laser optics housing unit. 4. Replace the IPU.
Description: Laser synchronizing detection error: end position [M] The laser synchronizing detection signal for the end position of LDB [K], [C], [M], [Y] is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: • Disconnected or defective harness to synchronizing detector for end position • Defective synchronizing detector board • Defective LD board or driver • Defective IPU
Remedy: 1. Check the connectors. 2. Replace the harness of the LD board. 3. Replace the laser optics housing unit. 4. Replace the IPU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.