Code: 161-03

Description: IPU error
The ASIC on the IPU fails to configure or initialize the DRAM.
Causes: • Defective IPU board
Remedy: Replace the IPU board.

Code: 165

Description: Copy Data Security Unit error
• The copy data security board is not detected when the copy data security function is set "ON" with the initial setting. • A device check error occurs when the copy data security function is set "ON" with the initial setting.
Causes: • Incorrect installation of the copy data security board • Defective copy data security board
Remedy: 1. Reinstall the copy data security board. 2. Replace the copy data security board.

Code: 185

Description: CIS communication error Error occurs during ASIC register's automatic initialization on the CIS, or during transmission between the CIS - DF.
Causes: • Harness between the CIS - DF is disconnected • CIS defective
Remedy: 1. Check or replace the harness (CN220 or CN210 on the DF main board) between the CIS and DF. 2. Replace the CIS on the DF.

Code: 186

Description: CIS LED error
LED on the CIS causes an error.
Causes: • During initializing, the ratio of the average between leading-edge area and rear-edge is out of range. • During scanning, the shading data peak is under the standard value. • Harness CN210 and CN220 on the DF are disconnected.
Remedy: 1. Check or replace the harness (CN220 or CN210 on the DF main board) between the CIS and DF. 2. Replace the CIS on the DF.

Code: 187

Description: CIS black level error
The black level scanned by CIS is abnormal. The black level average of R, G or B is not within range (2 to 62). 0 < Calibrated Black data level < 255 (10bit).
Causes: • Defective CIS
Remedy: 1. Check or replace the harness (CN220 or CN210 on the DF main board) between the CIS and DF. 2. Replace the CIS on the DF.

Code: 188

Description: CIS white level error
The shading data peak detected from the CIS is abnormal.
Causes: • Defective CIS
Remedy: 1. Check or replace the harness (CN220 or CN210 on the DF main board) between the CIS and DF. 2. Replace the CIS on the DF.

Code: 189

Description: CIS gray balance adjustment error
The adjustment error occurs during the test after adjusting the gray balance.
Causes: • Defective CIS
Remedy: 1. Retry the gray balance adjustment. 2. If the machine does not recover, do the following steps. • Turn off the machine. • Make sure CN210 and CN220 are connected firmly. • Turn on the machine. 3. If the machine does not recover, replace the CIS.

Code: 195

Description: Serial Number Mismatch
• Serial number stored in the memory does not have the correct code.
Causes: • NVRAM defective • BICU replaced without original NVRAM
Remedy: 1. Check the serial number with SP5-811-002. 2. If the stored serial number is incorrect, contact your supervisor.