Description: Development motor error: C
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the K, M, C, or Y, development motor.
Causes: • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective
Code: SC327
Description: Development motor error: Y
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the K, M, C, or Y, development motor.
Causes: • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective
Code: SC336
Description: Developer set error: K
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: 1. Open the front door. 2. Pull out the film seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for Y
Code: SC337
Description: Developer set error: M
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: 1. Open the front door. 2. Pull out the film seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for Y
Code: SC338
Description: Developer set error: C
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: 1. Open the front door. 2. Pull out the film seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for Y
Code: SC339
Description: Developer set error: Y
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: 1. Open the front door. 2. Pull out the film seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for Y
Code: SC348
Description: Toner supply motor error
2 sec. after the motor START signal is output, a LOCK signal cannot be detected.
Causes: • Motor harness disconnected, loose, or defective • Toner pump overload • Sub hopper overload • Toner hopper motor defective
Code: SC350
Description: Developer Fill Error: K
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.