Description: Sensor 4: Pressure Roller Center Disconnection 0 degrees or lower was detected for (t1) seconds consecutively. Number of times: 10 or more D135 (Japan): 75 (seconds) D136 (Japan)/D135 (NA): 75 (seconds) D136 (NA)/D135 (EU)/D136(EU): 75 (seconds) D137 (Japan): 75 (seconds) D138 (Japan)/D137 (NA)/D138 (NA)/D137 (EU)/D138 (EU): 75 (seconds) Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off).
Description: Sensor 4: Pressure Roller Center: Overheat detection (software) (T3) degrees centigrade or higher was detected for (t6) seconds consecutively. Number of times: 10 or more D135 (Japan):T3 = 220, t6 = 1 D136 (Japan)/D135 (NA): T3 = 220, t6 = 1 D136 (NA)/D135 (EU)/D136(EU): T3 = 220, t6 = 1 D137 (Japan): T3 = 220, t6 = 1 D138 (Japan)/D137 (NA)/D138 (NA)/D137 (EU)/D138 (EU): T3 = 220, t6 = 1 Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off).
Causes: • Triac shorted. • IOB board defective.
Remedy: • Replace the IOB board. • Replace the unit.
Description: Pressure Roller Center: Overheat detection (hardware) Hardware detection of overheat condition. The pressure roller center thermopile was detected as the cause.
Causes: • IOB defective • Fuser control software running out of control • Triac damaged (shorted). • Pressure roller center thermopile defective
Remedy: • After removing the cause of the SC, Set "Fusing SC Clear" in the SP mode. • If necessary, replace: IOB/pressure roller center thermopile/AC drive.
Description: Heater 2: Heater Continuously On (Sensor 4: Thermopile: Pressure Roller Center) Target temperature was not reached (t7) seconds after reload. Time elapsed after reload (excluding paper transport time) (t8) D135 (Japan): t7 = 90, t8 = 90 D136 (Japan)/D135 (NA): t7 = 90, t8 = 90 D136 (NA)/D135 (EU)/D136(EU): t7 = 90, t8 = 90 D137 (Japan): t7 = 90, t8 = 90 D138 (Japan)/D137 (NA)/D138 (NA)/D137 (EU)/D138 (EU): t7 = 90, t8 = 90 Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off).
Description: Fusing jam: 3 counts Fusing jam (fusing exit sensor late jam) was detected 3 times consecutively. Details: This SC can be set ON/OFF. The factory setting is OFF; set it ON when requested by the customer. SP1-142-001: 0: OFF (factory setting) 1: ON (set by service personnel at the request of customer) This prevents collateral problems (such as thermistor floating) that may be caused by repeated jams in the fusing unit. • The jam counter is not reset by power off/on. • When paper is output successfully, the jam counter is reset.
Causes: • Paper jam in the fusing unit • Sensor defective
Remedy:
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.